 Case History:
College of Creative Studies

 Location
   Detroit, Michigan

 General Description
   College residential building built circa 1928
   Restored one set of riser servicing 24 bathrooms
      each with toilet, lavatory, and bath/shower

 Risers
   Material
        Galvanized
   Condition
        Poor to Fair
   Type
        Inverted - Gravity Fed
            from Water Tank in Penthouse
   Pipe Diameters and Transitions
         Hot      2" - 1-1/2" - 1-1/4" - 1"
         Cold  
  2-1/2" - 2" - 1-1/2" - 1-1/4" - 1"
         Turns   None

 Laterals
   Material
         Galvanized
   Condition
         Poor to Severely Deteriorated
   Pipe Diameters and Transitions
         Hot      1/2" - 3/4"
         Cold  
  1/2" - 3/4" - 1"
         Turns   Multiple 90s and 45s

 Restored Life Expectancy
   Life expectancy of restored riser and laterals is
   50 to 70 years with no further mineral build up
   or corrosion

 Benefits
   Increased Life ~ Minimal Demolition/Restoration
   Restored Pipe Diameter ~ Brown Water Eliminated
   Barrier Epoxy Coating Prohibits Mineral Build Up

 Link for CCS pdf
 


 Case History:
Parklane Towers

 Location
   Dearborn, Michigan

 Problem
 The aging galvanized water distribution risers in the twin
 15 story Parklane Towers had become deteriorated with
 mineral build up and corrosion resulting in restricted flow
 and brown water. Underground 4" pipes needed to be
 restored from the pump room to the main buildings, as
 well as a 4" diameter central riser servicing main
 bathroom groups and four 2-1/2" galvanized graduated
 to 3/4" copper tenant risers for the floors in each tower.

 Traditional Restoration
   • Break slab, dig and replace underground pipe
   • Abate all asbestos contaminated areas
   • Shut down water to risers
   • Disconnect all lateral branches
   • Break our firewall for central riser re-pipe
   • Major inconvenience for tenants

 APL Restoraiton Using APL2000 Technology
   • Risers cleaned and restored with building occupied
   • Minimized Asbestos Abatement Issues
   • Little demolition and restoration costs
   • Restored pipe diameter - water flow - no brown water
   • No further mineral build up or pipe corrosion
   • NSF-61 Certified - Environmentally Safe
   • Warranty: Up to 10 years limited
   • Life Expectancy: 50 - 70+ years

 Link for Parklane Towers pdf